116 Appendix A User Information and Instructions P/N 9040322
Terminal 155i Alarms
Alarm and Malfunction Indicators
Terminal 155i indicates an alarm or malfunction by flashing or continuously lit LEDs
(green and red).
When Terminal 155i’s LEDs indicate an alarm, its display shows information about
the alarm. Table 28 shows how to identify which alarm Terminal 155i is indicating.
The animal has a code defined in
AfiSheep/ AfiGoat as a "High level
health code ".
Special start required
External start is blocked
"Animal ID" field and
"Health code" field are
blinking
The animal has a code defined in
AfiSheep/ AfiGoat as a "Medium
level health code ".
Special start required
"Animal ID" field and
"Health code" field are
blinking
The animal has a code defined in
AfiSheep/ AfiGoat as a "Low level
health code".
"Animal ID" field and
"Health code" field are
blinking
The milk has conductivity high
than alarm conductivity level
defined by AfiSheep/ AfiGoat
"Animal ID" field and "actual
conductivity" field are
blinking
Removing conditions are fulfilled,
but the milk yield is low than
minimum level predicted by
AfiSheep/ AfiGoat
"Animal ID" field and
"predicted milk yield" field
are blinking
High conductivity alarm and
Low Milk Yield alarm
simultaneously
"actual conductivity" field
and "predicted milk yield"
field are blinking
Three sequential animals have
milk conductivity less than "6"
AfiFree units
"Stall number" field &
"actual conductivity" field
are blinking
"Stall number" field and
"Pulsation" field are
blinking with
Vacuum
Shutoff output
fault
Vacuum Shutoff output failed
"Stall number" field is
blinking and "Animal ID"
field blinks with